The first two authors contributed equally to this work.
In neurosurgical cases, problems related to wound healing can vary from simple wound dehiscence to multilayer defects. This study demonstrates an effective method to prevent persistent cerebrospinal fluid (CSF) leakage using reinforcing acellular dermal matrix in neurosurgical patients with wound dehiscence. A 52-year-old woman was admitted for management of recurrent glioblastoma. After tumor removal surgery, the patient experienced sustained CSF leakage from the wound despite reparative attempts. The plastic surgery team performed wound repair procedure after remnant tumor removal by the neurosurgery team. Acellular dermal matrix was applied over the mesh plate to prevent CSF leakage and the postoperative status of the patient was evaluated. No sign of CSF leakage was found in the immediate postoperative period. After 3 years, there were no complications including CSF leakage, wound dehiscence, and infection. We hereby propose this method as a feasible therapeutic alternative for preventing CSF leakage in patients experiencing wound problem after neurosurgical procedures.
In neurosurgical cases, complications in wound healing vary from simple wound dehiscence to complex multilayer defects, which can result in cerebrospinal fluid leakage and contamination [
In the past few years, acellular dermal matrix has been used for reconstruction following burns or complex wounds of the scalp [
A 52-year-old woman presented to the emergency room with clear discharge from her surgical wound. Medical history revealed that the patient had undergone surgery thrice for removal of brain tumor along with 30 sessions of cranial radiotherapy. The last surgery was performed 2 months before. During the procedure, the recurring tumor was successfully removed, and primary closure of the dura was performed using continuous locking sutures. One month following the surgery, the patient was discharged without any complications. However, on postoperative day 62, the patient visited our emergency room with discharge of fluid from the surgical wound and nose that appeared to be cerebrospinal fluid. The patient was admitted to the neurosurgery department, where a team added several sutures to the previous incision line and applied compressive dressing. Despite these procedures, the leakage persisted (
We first attempted negative pressure wound therapy, which promotes vessel destabilization and maturation. CuraVAC (Daewoong Pharm Co., Ltd., Seoul, Korea) was fixed to the shaved scalp using 3M Ioban 2 (3M Health Care Inc., St. Paul, MN, USA). One month following negative pressure wound therapy, persistent wound dehiscence was observed. We performed selective debridement and applied Dermabond on the incision line.
Due to non-improvement in the condition, the neurosurgery team decided to perform repeat surgery for remnant tumor removal and wound repair. In the operating room, following the previous operative incision, the neurosurgery team excised the remnant tumor with necrotic tissue and performed duroplasty with fascia lata. After duroplasty, a mesh plate was inserted as a calvarial substitute. The plastic surgery team joined the operation and applied a 4× 16 cm section of CGCryoDerm (CGBio Co., Seongnam, Korea) over the mesh plate, especially beneath the incision site to prevent cerebrospinal fluid leakage. A drain was inserted and primary closure was performed (
On postoperative day 2, the color of the drainage changed from serosanguineous into serous drainage which became nearly close to that of the cerebrospinal fluid. Under the judgement of neurosurgical experts, the drain was removed not to disrupt the cerebrospinal fluid circulation system. On postoperative day 8, the negative pressure wound therapy was stopped and no sign of leakage was observed. At the 5-month and 3-year postoperative follow-up, there were no complications including cerebrospinal fluid leakage, wound dehiscence, or infection (
Cerebrospinal fluid leakage is a common complication after neurosurgical procedures. Cerebrospinal fluid leakage and other factors such as cortisone therapy, irradiation, infection, and repeated (three times or more) attempts at wound closure have been associated with wound-related complications [
The advantage of reinforcing acellular dermal matrix over the mesh plate is that it can potentially eliminate flap donor-site morbidity and complications. In addition, this acellular dermal matrix can be customized to any defect size, and is readily available for use.
Acellular dermal matrix has been used in various fields. Few studies have demonstrated the effectiveness of acellular dermal matrix reinforcement in prevention of cerebrospinal fluid leakage [
In previous studies [
While several variants of acellular dermal matrix are commercially available, we used CGCryoDerm that has more preserved dermal structure owing to the manufacturing process, which involves freezing without drying. CGCryoDerm also contains abundant growth factors for angiogenesis and recellularization. Acellular dermal matrix is beneficial in reinforcing the native dermis, which can act as a double barrier to cerebrospinal fluid leakage. However, cautious postoperative evaluation is necessary since acellular dermal matrix may increase the risk of development of infection.
Although the patient in the present study had associated risk factors that included many prior sessions of radiation therapy, along with more than three wound repair procedures, she was free of complications including cerebrospinal fluid leakage and wound dehiscence at 3 years, postoperatively. This case illustrates that reinforcement with acellular dermal matrix can be a surgical option for preventing cerebrospinal fluid leakage even in problematic wounds.
No potential conflict of interest relevant to this article was reported.
The study was approved by the Institutional Review Board of Samsung Medical Center (IRB No. 2019-09-020-001) and performed in accordance with the principles of the Declaration of Helsinki. Written informed consent was obtained.
The patient provided written informed consent for the publication and the use of her images.
Acellular dermal matrix was applied over the mesh plate, especially beneath the incision site to prevent cerebrospinal fluid leakage. A drain was inserted and primary closure was performed followed by vacuum-assisted closure dressing
Supplemental data can be found at:
Various methods used to prevent cerebrospinal fluid leakage. (A) Additional sutures applied at the incision site were unsuccessful in stopping the leakage. (B) Preoperative brain computed tomography imaging of the patient, which presents extradural fluid collection in the right parietotemporal area.
Surgical process of acellular dermal matrix augmentation. (A) Neurosurgery team excised the remnant tumor followed by duroplasty and mesh plate insertion. (B) Plastic surgery team applied a section of acellular dermal matrix over the mesh plate, especially beneath the incision site. (C) A drain was inserted and primary closure was performed.
Photographs after the final operation. (A) Photograph taken at the 5-month postoperative follow-up. (B) Photograph taken at the 3-year postoperative follow-up. No complications were found in patient including cerebrospinal fluid leakage and wound dehiscence.
Five-month postoperative brain magnetic resonance imaging (MRI) of the patient. MRI T2 weighted image shows cerebrospinal fluid accumulation still exists over the mesh plate (black line with patterned protuberance). Integrated acellular dermal matrix (black thin line) is found right above the outer cerebrospinal fluid accumulation which acts as an outer barrier.