Abstract
PURPOSE
The goals of a blow-out fracture reconstruction are to restore the osseous continuity, provide support for the orbital contents and prevent functional and anatomic defects. Over the past several years, a range of autogenous and synthetic implants have been used extensively in orbital reconstructions. None of these implants have any absolute indications or contraindications in certain clinical settings. However, in extensive blow-out fractures, it is difficult to restore support of the orbital contents, which can cause more complications, such as enophthalmos. This study examined the clinical outcomes of extensive or comminuted blow-out fractures that were reconstructed by the simultaneous use of a titanium mesh plate and Medpor(R). METHODS: Eighty six patients with extensive orbital fractures, who were admitted between March 1999 and February 2007, were reviewed retrospectively. The patients' chart and CT were inspected for review. Twenty three patients were operated on with both a titanium mesh plate (Matrix MIDFACE pre-formed orbital plate, Synthes, USA) and Medpor(R) (Porex, GA, USA). The patients underwent pre-operative CT scans to evaluate the fracture site and measure the area of the fracture. A transconjunctival approach was used, and titanium mesh plates were inserted subperiosteally with screw fixation. Medpor(R) was inserted above the titanium mesh plate. The patients were evaluated post-operatively for enophthalmos, diplopia, sensory disturbances and eyeball movement for a period of at least 6 months.
RESULTS
No implant-related complications were encountered during the follow-up period. Enophthalmos occurred in 1 patient, 1 patient had permanent sensory disturbance, and 3 patients complained of ocular pain and fatigue, which recovered without treatment. Although there were no significance differences between groups, the use of 2 implants had fewer complications. Therefore, it can be an alternative method for treating blow out fractures.
CONCLUSION
The use of both a titanium mesh plate and Medpor(R) simultaneously may be a safe and acceptable technique in the reconstruction of extensive blow-out fractures.
Keywords: Blowout fracture; Titanium mesh plate; Porous polyethylene
TOOLS
  • PDF Links   PDF Links
  • Full text via DOI   Full text via DOI
  • Cited  Cited
    Cited
    export Copy
    Close
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1,876 View
  • 0 Download
Related articles in ACFS

Treatment of Frontal Sinus Fractures According to Fracture Patterns.2009 October;10(2)



ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
AUTHOR INFORMATION
Editorial Office
Dept. of Plastic and Reconstructive Surgery Chonnam National University Medical School, 42 Jebong-ro, Dong-gu, Gwangju 61469, Korea
Tel: +82-62-220-6354    Fax: +82-62-220-6357    E-mail: office_acfs@kcpca.or.kr                

Copyright © 2025 by Korean Cleft Palate-Craniofacial Association.

Developed in M2PI

Close layer
prev next