Orbital wall restoration with primary bone fragments in complex orbital fractures: A preliminary study
Article information
Abstract
Background
We have reported orbital wall restoration surgery with primary orbital wall fragment in pure blowout fractures using a combination of transorbital and transnasal approach in pure blow out fractures. However, this method was thought to be difficult to use for complex orbital wall fractures, since the sharp screw tip that fixate the maxillary wall increases the risk of balloon ruptures. In this study, we reviewed 23 cases of complex orbital fractures that underwent orbital wall restoration surgery with primary orbital wall fragment and evaluated the result.
Methods
A retrospective review was conducted of 23 patients with complex orbital fracture who underwent orbital restoration surgery with primary orbital wall fragments between 2012 and 2019. The patients underwent orbital wall restoration surgery with primary orbital wall fragment with temporary balloon support. The surgical results were evaluated by the Naugle scale and a comparison of preoperative and postoperative orbital volume ratio. Complex fracture type, type of screw used for fixation and complications such as balloon rupture were also investigated.
Results
There were 23 patients with complex orbital fracture that used transnasal balloon technique for restoration. 17 cases had a successful outcome with no complications, three patients had postoperative balloon rupture, two patients had soft-tissue infection, and one patient had balloon malposition.
Conclusion
The orbital wall restoration technique with temporary balloon support can produce favorable results when done correctly even in complex orbital wall fracture. Seventeen cases had favorable results, six cases had postoperative complications thus additional procedure seems necessary to complement this method.
INTRODUCTION
The goal of orbital reconstruction is to restore ocular motility and to prevent enophthalmos by restoring the native orbital anatomy and volume, but operations on this kind of complex orbital fracture are technically demanding and pose a major challenge to orbital surgeons. Complex orbital fractures are an impure type of orbital fracture, as they involve not only the orbital walls, but also the orbital rim and adjacent structures, as seen in frontal, maxillary, and zygomatic fractures. Patients with these complex fractures require simultaneous reconstruction of the displaced orbital rim and mid-face buttresses and restoration of the orbital shape [1,2].
Most surgeons struggle to restore the shape of the orbit, since the orbital wall is so thin that it cannot be fixed firmly to its primary position, unlike mid-face buttresses. Therefore, it has become more common to reconstruct orbital wall fractures using various kinds of synthetic implants [3]. Although these implants are strong enough to maintain their shape and position in the orbital cavity, reconstructive surgery using implants has some drawbacks [2]. The author has reported an orbital wall restoration technique in which primary orbital wall fragment restored to its previous position and temporary extraorbital support is maintained with an inflated Foley catheter balloon in the maxillary sinus [1,2]. However, this orbital wall restoration method may be difficult to use for complex orbital wall fractures, since the sharp screw tip used for buttress fixation increases the risk of balloon rupture [4].
In light of this potential issue, we theorized that we could avoid balloon rupture by fixing the screw at the margin of the buttress, which would yield successful outcomes in complex orbital wall fractures. In this paper, we evaluated 23 patients who underwent complex orbital wall restoration using primary bone fragments with an uneventful postoperative course and favorable outcomes.
METHODS
Subjects
This retrospective study analyzed patients who underwent reconstruction of complex orbital wall fractures between 2012 and 2019.
Ophthalmic examination
Ophthalmic examinations for diplopia, extraocular muscle movement, and enophthalmos were done before surgery. Enophthalmos was measured using a Naugle exophthalmometer (Inami Inc., Tokyo, Japan) by measuring from the superior and inferior orbital rim to the apex of the cornea. Preoperative values were evaluated 1 day before surgery and follow-up was performed 6 months after treatment when atrophy and scarring of the orbital tissue were complete. All patients underwent computed tomography (CT) scans within 1 week after trauma and at 6 months after surgery. The volume of the orbit was calculated by applying integral calculus to the CT images. The orbital volume ratio (OVR) was obtained by comparing the volume of the injured orbit to that of the uninjured orbit.
Surgical techniques
After performing the forced duction test, open reduction of complex fractures was performed through standard approaches, such as the buccal sulcus, lateral eyebrow, and transconjunctival approaches.
Screws are usually fixed along the edges of the maxillary sinus, corresponding to vertical and horizontal facial buttresses such as inferior orbital rim, pterygomaxillary buttress and nasomaxillary buttress. After screw fixation, usually in the vertical and transverse facial buttresses to obtain adequate skeletal support, dissection was done until the fracture of the orbital floor was exposed. The orbital content herniated through the defect was repositioned and a curved Freer elevator was inserted transnasally into the maxillary ostium to restore the primary bone fragment of the fractured inferior orbital wall.
A 14-Fr or 16-Fr Foley catheter (Sewoon Medical Co., Ltd., Seoul, Korea) was then inserted through the maxillary ostium into the maxillary sinus. The Foley catheter balloon was inflated using saline solution mixed with radiopaque dye (Telebrix 30; Guerbet, Villepinte, France) until the orbital floor was restored with the primary bone fragment. Because the Foley catheter balloon placed within the sinus does not intersect with the facial buttress margin, the balloon is likely to avoid rupture caused by fixation screws (Fig. 1). Bony restoration of the orbital floor was followed by placing a porous polyethylene implant such as Synpor (Synthes Inc., West Chester, PA, USA) or Medpor (Porex Surgical Inc., Newnan, GA, USA) or a resorbable mesh plate such as Rapidsorb (Synthes Inc.) to bridge the remaining defect [5]. The balloon support was kept in position for 7–8 days.
Statistical analysis
The t-test was used to analyze perioperative differences in OVR and the Naugle scale. SPSS version 20.0 for Windows (IBM Corp., Armonk, NY, USA) was utilized for all analyses.
RESULTS
In total, 23 patients were treated with the standard open reduction method using the transnasal and transorbital approaches. Twenty-one patients were men and two were women (age range, 25–61 years; mean age, 38.6 years). The most common complex fracture type was zygomaticomaxillary complex fracture (14 cases), followed by nasomaxillary fracture (four cases), LeFort fracture (three cases), and maxillary fracture (two cases) (Table 1). The patients’ postoperative course was mostly successful, with a short-term complication rate of 26.0%. Shortterm complications included postoperative balloon rupture in three patients, soft-tissue infections in two patients, and balloon malpositioning in one patient (Table 2). Ruptured and malpositioned balloon cases were managed by removing the inserted balloon. Intravenous antibiotics were used to control soft-tissue infection patients which resolved within a week. All patients had a follow-up period of at least 6 months and showed favorable long-term outcomes (Fig. 2). The Naugle scale improved by an average of 0.27 mm and the OVR decreased by 7.05% on average (Table 3).
DISCUSSION
Historically, extraorbital support using a balloon was first reported in 1944 by Johnson, and cases where a Foley catheter was used for reduction of the anterior maxillary wall were first dealt with in 1975 by Oppenheimer [4,6]. Using the transnasal approach and temporary extraorbital support to restore the orbital floor was found to reduce the risk of volume change, postoperative implant shifting, and the size of the implant necessary for orbital wall restoration [1,2].
The maxillary sinus is pyramidal in shape formed of four walls; anterior, posterior, superior and medial. The superior wall is made up of the fragile orbital floor and the medial wall separates the sinus from the nasal cavity. It has the maxillary ostium located between the middle and posterior thirds of the ethmoidal infundibulum and tend to be positioned closer to the roof of the sinus than the floor. The author inserted a Foley catheter through the maxillary ostium to restorate the orbital floor from the maxillary sinus. In complex orbital wall fractures, it is necessary to fixate the mid-face buttress fracture with plates and screws, which may increase the risk of the balloon rupture due to the sharp screw tip. Contrary to the common belief that Foley balloons have a high risk of rupture when used in complex orbital wall fractures [4], the authors could reduce the balloon rupture rate to 13.0% (3/23 cases).
The transnasal balloon method is beneficial because it gives more support to the restored primary orbital wall fragment, though there is risk of rupture in some cases. When the round-shaped Foley balloon is inflated in the sinus, the balloon supports the center areas of each sinus wall of the pyramid, but there is space left at the edge of the maxillary sinus. Fixing the screw to the edge of the maxillary buttress can reduce the balloon rupture rate by preventing the screw tip from touching the balloon. We used short screws (<6 mm) to prevent the screws from touching the balloon, in addition, absorbable packing sponges such as Nasopore (Polyganics B.V., Groningen, Netherlands) could be inserted through the maxillary ostium to protect the Foley balloon from rupture. In our cases, balloon rupture was found in three of the 23 cases, but two occurred 4 to 5 days after surgery and only one occurred one day after surgery. Although balloon rupture occurs at a low rate, if a balloon rupture by the screw is expected, it may be necessary to use a relatively large implant in complex orbital wall fracture.
It is recommended that investigations with larger sample sizes be performed to obtain more information on the correlations between the complex fracture type and the complication rate. In conclusion, our surgical results from 23 patients with complex orbital wall fractures suggest that providing additional support from the maxillary sinus can yield good results and that this technique can be implemented effectively without significant risk of Foley catheter balloon rupture.
Notes
Conflict of interest
No potential conflict of interest relevant to this article was reported.
Ethical approval
The study was approved by the Institutional Review Board of Dankook University Hospital (IRB No. DKUH 2020-06-011) and performed in accordance with the principles of the Declaration of Helsinki.